Understand and Prevent Diesel Generator Abnormal Shutdowns
On this page
 
Diesel generator set is an important backup power supply, the reliability of its operation is often affected by various factors. Abnormal shutdown is a common generator failure. Abnormal shoutdown of diesel generator will not only interrupt the power supply, but also may cause immeasurable damage to the equipment itself and the working environment. Therefore, understanding the abnormal shutdown situation of diesel generator sets and taking effective preventive and maintenance measures are the key to ensure the continuity of power supply and equipment safety.
 

Abnormal Shutdown of Diesel Generator

 
The abnormal shutdown situation of diesel generator sets can be divided into two main types, and each type may be caused by different specific reasons. Understanding these causes can not only help us quickly identify problems, but also prevent shutdown events to a certain extent.
 
Sudden Stop of Operation: This is usually due to the exhaustion of fuel or a ruptured fuel line, causing the diesel generator to be unable to continue operating.
 
Stop with Speed Decreased: it may be due to water or air mixed in the fuel, resulting in discontinuous or even interrupted oil supply, or the governor, fuel injection pump or gear transmission damage, resulting in oil supply failure or oil supply timing is affected.
 

Causes of Diesel Generator Abnormal Shutdown

 
The specific reasons for abnormal shutdown of diesel generator sets can be analyzed according to the actual situation as follows.
 

1. Fuel System Problem

Running out of fuel or ruptured lines: Running out of fuel or ruptured fuel lines can interrupt the fuel supply and prevent the diesel generator from continuing to operate.
 

2. Fuel Quality

Water or air mixed into the fuel: if the fuel is mixed with too much water or air, it will lead to air resistance or water resistance, making the fuel supply discontinuous, or even a short interruption, resulting in an emergency shutdown of the diesel generator.
 

3. Fuel Injection Pump Component Failures

Fuel injection pump spring break or plunger stuck: The spring, plunger or oil outlet valve in the fuel injection pump failure, will lead to fuel supply interruption or abnormal, and eventually lead to the shutdown of the diesel generator.
 

4. Governor Issues

Governor spring break or rack damage: Damage to the spring or rack damage in the governor will make the governor unable to properly adjust the fuel supply, resulting in automatic deceleration or even shutdown of the diesel generator.
 

5. Transmission System Failures

Gear transmission damage or fuel injection pump transmission problem: If the gear transmission of the diesel generator is damaged, or the fuel injection pump transmission fails, the timing of the fuel supply will be affected, and ultimately the normal operation and shutdown of the diesel generator will be affected.
 

6. Valve System Problem

Stuck valve or broken valve spring: Although not common, a failure of the valve system (such as a stuck valve or broken valve spring) can also affect fuel combustion efficiency and ultimately lead to the shutdown of a diesel generator.
 

7. Automatic Shutdown Safety Device Activation

Low oil pressure or excessive speed: Diesel generators are equipped with automatic shutdown safety devices, when the oil pressure is too low or excessive speed will automatically stop to protect the safety of equipment and operators.
 

Preventive Measures & Maintenance Suggestions

 
In order to effectively prevent abnormal downtime of diesel generators, the following are some important preventive measures and maintenance recommendations:
 
Regular Maintenance: Replace the oil, filter and air filter regularly, clean the fuel system and radiator, and ensure that the generator set runs in good working condition.
 
Fuel Management: Ensure adequate fuel supply, regularly check fuel quality and pipeline integrity, and treat water or air in the fuel system to prevent it from affecting the quality of the fuel supply.
 
Battery Management: Periodically check the battery status and power level to ensure that the battery can reliably start the generator, especially in emergency situations.
 
Electrical System Inspection: Check the electrical system of the generator regularly to prevent potential electrical failures and ensure the normal operation of the electrical equipment.
 
Load Planning: Reasonable load planning, avoid long-term overload operation, reduce equipment wear and load pressure of the generator.
 
In short, regular maintenance and careful troubleshooting can ensure the stable operation of diesel generators. By implementing effective preventive measures, such as regular replacement of key components, strict management of fuel quality, guarantee of battery power supply capacity, and reasonable load planning, the probability of abnormal downtime of diesel generators can be reduced, and the reliability and continuous operation of the equipment can be improved.
 
 