Troubleshooting Gasoline Generators After Inactivity
On this page
 
Gasoline generators are widely used for their portability and reliability. However, they often face startup issues after being inactive for an extended period. Understanding the causes of this problem and the corresponding solutions is essential for maintaining and using gasoline generators effectively.

Gasoline Shelf Life and Quality

 
Gasoline serves as the primary fuel for generators, and its quality directly impacts engine performance. Different types of gasoline have varying shelf lives:
 
Pure Gasoline: Shelf life is approximately three months. During this period, the gasoline maintains its performance.
Ethanol Gasoline: Shelf life is relatively short, about one month, as it tends to absorb moisture and degrade quickly.
 
Over time, gasoline can oxidize and evaporate, leading to sediment and impurities. Its color may change from clear and transparent to dark yellow or cloudy, accompanied by a pungent odor. To ensure the proper operation of the generator, users should check the gasoline quality before use. It is advisable to take out a small amount of gasoline and observe:
 
Viscosity: If the gasoline becomes thick, it may be degraded.
Color Change: If the color becomes darker and murky, it should be replaced with fresh gasoline.
Impurities: If there are floating particles, it indicates contamination, and the gasoline should not be used.

Carburetor Clogging Issues

 
The carburetor is a critical component of gasoline generators, responsible for mixing gasoline with air and delivering it to the engine. If the generator has been unused for a long time, the carburetor may become clogged due to the deterioration of gasoline. Moisture in degraded gasoline can combine with oxygen in the air, leading to rusting of internal metal parts and the formation of impurities. These impurities can clog the carburetor's fuel delivery channels, resulting in insufficient fuel supply.  
Carburetor Cleaning: Use a carburetor cleaner to remove carbon deposits and impurities from the carburetor.
Replace the Carburetor: If clogging is severe and cannot be cleared, the carburetor must be replaced to ensure proper fuel flow.
Regular Maintenance: After each use, close the fuel valve and drain any fuel remaining in the carburetor bowl to keep it dry and clean, thus reducing the risk of clogging.

Checking Oil and Fuel Levels

 
Before starting the generator, it is crucial to check the freshness of the oil and gasoline (or diesel). The effective life of oil and fuel typically lasts for three months, and after that, they lose their performance and viscosity, potentially leading to starting difficulties.
Oil Inspection: Ensure that the oil is new and sufficient in quantity; if the oil appears dark or has sediment, it should be replaced.
Fuel Level Check: Verify that the fuel tank has sufficient fuel and that there are no leaks in the fuel lines or connections. Insufficient fuel can affect starting and may damage the engine.

Spark Plug Inspection and Maintenance

 
The spark plug is a key component of the ignition system, responsible for igniting the gasoline-air mixture. If the generator has been unused for a long time, the spark plug may become damp due to gasoline evaporation, resulting in ignition failure.
Relevant Solutions
Spark Plug Inspection: Remove the spark plug and check for carbon buildup or damage. Clean it if necessary or replace it if it's too degraded.
Handling Dampness: Wipe the spark plug dry, and if there is moisture, lightly soak it with gasoline before reinstalling to ensure proper ignition.

Pre-Startup Preparations

 
Before starting the generator, it is essential to perform a comprehensive check to ensure a smooth startup. Users should pay attention to the following areas:
Sufficient Fuel: Ensure that the fuel tank is adequately filled and that there are no leaks.
Cooling System: Check the water level in the cooling system to ensure it is clean and leak-free to prevent overheating.
Fan Belt: Inspect the tension of the fan belt to ensure it is in good condition and functioning correctly.
Instrument Functionality: Confirm that all gauges are complete and functional to monitor engine status effectively.

Startup Procedure

 
When starting the generator, follow these steps to increase the chances of a successful startup.
 
Press the Start Button: Hold the button down for 3 to 5 seconds. If it fails to start, wait for 20 seconds before trying again.
Repeated Startup Failures: If multiple attempts to start the generator are unsuccessful, stop and check for issues with the battery voltage or fuel line.
Observe Oil Pressure: Watch the oil pressure during startup; if there is no reading or it is low, stop immediately to check for potential damage.
 
After successfully starting, the generator should run at low speed for 3 to 5 minutes to allow temperature and oil pressure to stabilize before beginning normal operation. During this period, watch for any unusual noises to ensure all components are functioning correctly. Once frequency and voltage reach rated levels, the generator can begin supplying power.

Conclusion

 
By following the detailed steps outlined above, you can effectively resolve the issues of gasoline generators that fail to start after long periods of inactivity. Regular inspections and maintenance, along with timely replacement of degraded gasoline and oil, will significantly extend the life and reliability of the generator, ensuring it is ready to operate whenever needed. Good operational habits and maintenance awareness are crucial for keeping the generator running efficiently and safely, providing a reliable power supply when required.
 
 