Some Challenges in Containerized Diesel Generator Applications
On this page
With the continuous development of industrialization and urbanization, the stability and reliability of power supply have become increasingly important. In many cases, especially in areas far from city centers or with unstable power supply, the demand for backup power sources is becoming more prominent. Containerized diesel generator have emerged as one of the preferred options for backup power due to their convenience, flexibility, and efficiency. However, in practical applications, containerized diesel generator also face some challenges that need to be addressed through innovative solutions.
1. Issues with Parallel Switchgear Systems
Currently, most containerized diesel generator have separate arrangements for the diesel engine and switchgear, leading to several problems. Firstly, the distance between them makes it difficult to observe the status of both the generator and the switchgear simultaneously during testing and operation. Secondly, the long-distance cable laying increases cable investment and is prone to cable damage, thus complicating construction. One solution to these problems is to implement parallel connection of generator using containerized switchgear systems near the diesel engine systems. This not only reduces the number of cables required but also saves on civil construction investment, achieving a simple connection between standby diesel systems and load distribution systems.
2. Environmental Impact Issues
The exhaust from containerized diesel generator can have an impact on both the environment and the generator themselves. Due to the high exhaust velocity and temperature, several considerations need to be taken into account: Firstly, no green belt should be within 10 meters of the container exhaust to prevent damage to vegetation from excessive heat. Secondly, efforts should be made to avoid discharging hot air onto roads and sidewalks to prevent harm to pedestrians. Lastly, proper isolation of cold and hot air channels should be designed to prevent thermal backflow from affecting other generator .
3. Variability in External Dimensions
Containerized diesel generator exhibit significant variations in external dimensions, primarily due to factors such as elongated air intake and exhaust channels to reduce noise levels, installation of switchgear within the container, provision of larger maintenance spaces, transportation considerations, and site layout constraints. While this variability increases project complexity and imposes higher requirements on design and site layout, it also offers more flexible options for different scenarios.
4. Comprehensive Consideration of Solutions
Despite the advantages of containerized diesel generator in shortening construction cycles and enhancing flexibility, challenges arise from the extensive civil engineering required for supporting oil systems. Furthermore, the distance between diesel engines and parallel switchgear poses complexities in engineering interfaces and operational management. Therefore, when selecting diesel generator , users should consider various factors comprehensively and choose the most suitable type and configuration based on their actual needs.
In conclusion, although containerized diesel generator face challenges in practical applications, these challenges can be overcome through scientific and reasonable design and technological improvements. By doing so, more efficient and reliable backup power systems can be realized, providing robust support for the stability and reliability of power supply.